Showing posts with label buy halon. Show all posts
Showing posts with label buy halon. Show all posts

Thursday, July 21, 2016

Marine Fire Suppression....No Worries with A-Gas

The Marine fire protection industry seems to bring lots of unease. Lots of factors play into the safety and sustainability of the systems on many vessels. This was an interesting article Marine Fire Protection: An Ungoverned Space. 






At A-Gas Americas you never have to wonder about the quality of product being filled into your Clean Agent marine cylinders. Each tank is shipped with a Certificate of Analysis, providing you and your customer with peace of mind. Contact us today for a quote!



Thursday, February 4, 2016

Purchase Clean Agents and get Recharges with Rebecca!


Rebecca Magers has joined the A-Gas Americas Fire Protection team! She is here to help you with all of your Clean Agent needs. Bulk, Recharges, whatever you need, she is ready to assist you!

Welcome Rebecca and Brent!

Good Morning,
I am pleased to introduce the newest members of our Fire Protection team!  With the addition of Rebecca and Brent,  A-Gas Americas formerly RemTec International will continue to offer the best Total Solutions and Service available in the recycle, reclaim, and recharge industry.   Rebecca and Brent will be joining Eric, Deann, Tammy, Nick or myself to provide you with competitive quotes for our Platinum Recharge Servers or a quote to buy your Halon.  Give us a call at 800-372-1301 !!!
·         Rebecca Magers will be the new Sales manager. Rebecca has a vast background in sales and marketing, account management, business development, and customer service. Rebecca will be responsible managing the sales strategy for fire protection alternative agents and recharging business, looking for ways to grow the market to meet our overall growth targets. 

·         Brent Gase is joining us as an Assistant Buyer. Brent has previous experience in retail sales, and a background in Fire Protection Technology.
 


Thursday, January 28, 2016

FFEDA Schedule of training for 2016

FFEDA Events & Training for 2016

FFEDA Members, 
We hope you had a wonderful holiday and new year! Please see below for upcoming events with FFEDA:

2016 FFEDA Events Calendar

March 19, 2016       
FFEDA Board Meeting and Educational Seminar
Florida State Fire College - Ocala, FL
No hotel affiliated with this seminar - 
all events at College

June 23-25, 2016      
FFEDA Annual Conference & Trade Show
Marriott Orlando World Center
8701 World Center Drive - Orlando, FL 32821
                                     
August 20, 2016      
FFEDA Board Meeting and Educational Seminar
Naples Grande Beach Resort
475 Seagate Drive - Naples, FL 34103
                                   
November 5, 2016   
FFEDA Board Meeting and Educational Seminar
Hilton Sandestin Beach Golf Resort & Spa
4000 Sandestin Blvd South - Miramar Beach, FL 32550
 

Tuesday, November 24, 2015

Happy Thanksgiving!

Happy Thanksgiving from A-Gas Americas. As a Reminder We will be CLOSED for normal business on Thursday November 26th & Friday November 27th for the Thanksgiving Holiday. We are available for Emergency recharges! If you have an Emergency and need immediate assistance please contact Terri on the Emergency Recharge Hotline 419-466-6238! Thank you and have a safe and blessed holiday!




Wednesday, August 12, 2015

Marine industry is moving towards Novec over Halon



This article touches on the move for the Marine industry to stop relying on Halon for critical use.





http://www.marinelink.com/news/offshore-workboat-safety391130.aspx

Tuesday, June 9, 2015

Wednesday, May 6, 2015

Passing of Mel Getz

It is with great sadness we share this news....

  
 Shared by Rod Getz,  Getz Fire Equipment
  
It is with deep sadness, but with Joy to announce that my Father Melvin Getz passed away early last night (12:15 am, on 05/05/15). He had suffered so long and in the Hospital for over 6 weeks, it was a blessing for the Lord to take him home. He told the family 10 days ago that he was ready and wanting to go see Jesus and be in Heaven. The Angels took him there quietly and peaceful.

He loved our business and industry and will always be my "Mentor and Hero".

Visitation will be on Thursday at Davison-Woolsey-Wilton Funeral Home (2408 West Willow Knolls Dr., Peoria, IL 61614):
2:00 pm to 4:00 pm and 6:00 pm to 8:00 pm
Funeral will be @ Apostolic Christian Church on Friday @ 10:00 am

Thanks for all your prayers. God Bless!

Rod Getz
President/Owner
GETZ FIRE EQUIPMENT




Our thoughts are with our friends at Getz Fire Equipment during this difficult time. Mel was a trailblazer and an integral part in making our industry what it is today. 

Friday, November 21, 2014

Halon Phase out.

Click here for the original Aritcle: http://www.ainonline.com/aviation-news/aerospace/2014-11-20/halon-phaseout-proposed-easa

Halon Phaseout Proposed by EASA


 - November 20, 2014, 1:45 PM
The European Aviation Safety Agency proposed a phase-out schedule for the use of halon in fire extinguishers in the cabins and lavatories of future Part 25 business aircraft and airliners, as well as Part 29 rotorcraft. It claims that there are currently or soon will be two non-halon alternative fire-extinguishing agents available for these compartments.
However, for APU and engine compartments, the agency is taking a “do nothing” position until weight and other technical issues for alternative fire-extinguisher agents are solved. The objective of the proposal is to “progressively mitigate the environmental impact that halon has on the atmosphere and climate change,” EASA said.
The proposed schedule calls for the replacement of halon in lavatories on newly produced aircraft starting on Jan. 1, 2016, and in handheld extinguishers on newly built aircraft starting Jan. 1, 2019. End dates for the use of halon on current and new type-certified aircraft are already in effect under EU regulations. A second proposal will address smaller airplanes and some rotorcraft used in international operations.

Monday, October 6, 2014

Fire Prevention Week 2014




Take Action to Prevent Fires: Protect your Family!

Oct. 5-11 is National Fire Prevention Week. In 2010, there were 3,100 unintentional deaths related to fire, smoke and flames, according to the Council's Injury Facts, 2012 Edition.
The risk of fire increases as we head into the cooler months. The National Safety Council asks each of us to take a few moments to prevent fires in our homes. Make your family safer by completing a home fire safety checklist and identifying fire risks in your home.

Steps to prevent fires:
  • Have properly working smoke alarms
  • Have chimney's cleaned and inspected yearly.
  • Be extremely careful when using space heaters.
  • Never leave candles unattended.
  • Don't leave your dryer running when you leave the house or go to bed for the night.
  • Test smoke alarms and carbon monoxide detectors monthly and change the batteries at least once a year
  • Place smoke alarms on each floor of your home and in each bedroom
  • Plan a family escape route and practice it once a month
  • Install a home sprinkler system if three or more stories
  • Place fire extinguishers throughout your home and make sure everyone in the house knows how to use them
  • Check your Home Heating and Air conditioning units for proper functionality.
  • Monitor extension cord use, and make sure heating and cooling units are not plugged into there.
Additional links with INFO For Fire Prevention Week



Tuesday, August 19, 2014

Largest Novec System in the country

Project profile: Installing a large clean agent system in a complex environment

A government data center opted for a clean agent suppression system to protect its mission critical facility.

08/07/2014

Figure 1: This shows the primary and secondary clean agent tank installation in the data center. Courtesy: Southland IndustriesSouthland Industries recently designed and installed one of the largest clean agent fire suppression systems in the nation. The stakes were high as the goal of the project was to protect sensitive data stored on hundreds of servers within a large government facility. The project was particularly complex not only due to its large size and stringent standards for security, but also because it needed to seamlessly integrate with a double interlock pre-action system and an energy-efficient containment method of air cooling.
The immediate challenge facing the design team centered on accommodating the agency’s requirement that the building have continuity of operations. The agency needed to be able to perform system maintenance and upgrades without losing power to the system or any of its functionality. Any kind of system disruption—even one consisting of only a few minutes—was simply not acceptable.
Designing and installing this clean agent system required not only meticulous planning, but also creative thinking that led to a set of innovative and smart solutions for the building owner. It served as a reminder that regardless of any apparent incompatibilities among systems performing different functions, there are ways to design and structure them so they operate as a cohesive whole.
To ensure continuity of operations, project engineers designed a double interlock pre-action system to reduce the chance of accidental water discharge in the event of a fire. This would assure that water would only be discharged as a last resort in the 66,000-sq-ft data center space. As a first line of defense, a clean agent system using 3M NOVEC gas would be used.
Figure 2: Installation, accessibility, and serviceability are key considerations in the storage tank arrangement. Courtesy: Southland IndustriesInstalling a clean agent system in such a massive area required a creative approach by the team. Regulations required that clean agent “storage containers shall be located as close as possible to or within the hazards they protect” (NFPA 2001, Section 4.1.3.2). But the configuration of the building was not conducive to situating the clean agent system close to these protected areas. The server room and mechanical gallery are located in the center of the second floor over a 3-ft raised floor. The ceiling height of the server room is approximately 12 ft, and the space above the ceiling to the deck is approximately 4 ft. The electrical power supply via switchgear equipment is located directly below the server room space. All of this made it impractical to place the clean agent tanks on the same floor as the servers.
Given these constraints, the team determined that the best solution would be to locate the clean agent primary and secondary supply tanks on the ground floor, even though the protected hazard—the servers and mechanical gallery—are located on the second floor, 20 ft above and several hundred pipe lengths away.
This complicated matters even further, requiring the team to ensure the clean agent system’s fire-extinguishing gases could just as efficiently reach the protected areas as they would if they were located closer to them. This meant making sure that the system was equipped with the appropriate amount of gas and was forceful enough to pump that gas into the areas.
None of the clean agent systems certified at that time were right for the job. The project required a newer system that had a higher discharge pressure. After thorough evaluation and analysis of needs, the team eventually settled on the 500 psi NOVEC 1230. The system was so new that it was still going through its final approval process by UL, a third-party listing agency, as it was being installed. A few months before the project was turned over to the owner, the system gained official UL approval.
In addition to the many challenges already identified, the team needed to address the issue of arranging the various fire life safety systems and MEP trades and equipment in a limited amount of space. The fire suppression piping, along with the other trades, required detailed coordination to prevent interference and a lack of constructability. To prevent potential conflicts, the piping was designed, planned, and coordinated in 3D to reduce field changes. This allowed for the inclusion of bracing in the clean agent piping (similar to seismic bracing) to hold the pipes in place against the force of pressure that is exerted when the clean agent gas is discharged. By strategically locating the pipe, any potential interference with the other trades was prevented.
Another focus of concern was the need to prevent pipe corrosion. It was important to make space for a nitrogen system to prevent corrosion of the pipes of the double interlocked pre-action system, which employs schedule 40 black steel pipe. Concern about future corrosion prompted the pre-action system to be supervised by an inert gas such as nitrogen in lieu of standard air. However, space was not made available on the second floor to accommodate the infrastructure needs of the nitrogen system. As a result, the nitrogen generator and storage tank had to be located on the first floor in the clean agent storage tank room. From there, the supervisory nitrogen is piped up from the first floor to the pre-action valves on the second floor. The pre-action valve is required to automatically revert to a non-interlock configuration in the event of a power loss. Upon the return of power, the pre-action valve returns to its standard release method.
Finally, the project also needed to meet the requirements of and be certified to U.S. Green Building Council LEED Gold, version 3.0. It would be registered through the Green Building Certification Institute, with performance goals based on a “high-performance green building” as defined by the Energy Independence and Security Act of 2007.
To reach LEED certification in a building with many servers, the agency employed the containment method using barriers to trap and direct airflow to control cooling. The challenge with this method, however, is that the structure created obstructions that would make it difficult for the clean agent gas to reach it. The hot aisle containment areas are large enough to walk in and therefore require sprinkler protection as well as clean agent protection. The aisle utilized ceiling grids down the center for lights and fire protection devices but had 2-ft-wide open areas along the length of the enclosure. To address this, the project team altered the clean agent nozzle locations so that they entered into each of the containment areas.

Corey Wallace is an associate principal engineer with Southland Industries. He holds a bachelor’s in mechanical engineering from the University of Mississippi and a master’s of engineering management from Christian Brothers University.

Wednesday, July 2, 2014

Fire Suppression Saves Restaurant



Fire Suppression System at a New Jersey Pizza Hut saved the building.

Fire Suppression System Saves Toms River Pizza Hut
Restaurant now back open after fire damage contained to one deep fryer
Posted by Daniel Nee (Editor) , June 26, 2014 at 07:07 PM

Fire officials in Toms River say the township's Pizza Hut restaurant was protected by a fire suppression system installed last year when the restaurant had a new deep fat fryer installed in its kitchen.

Click here for the full story: http://tomsriver.patch.com/groups/police-and-fire/p/fire-suppression-system-saves-toms-river-pizza-hut